The releases of the stable channel, taken from the signed update index when each one is published. Security releases are marked; each CVE in a shipped component is listed with the days it took us from its publication to the fix.
sequence 267
1.2.57
ReleaseLatest
Adopt: every block now says in plain words what blocks, who made it and when (if the router knows), and what to do. When the router can fix it safely, one button does it.
A hand-made interface of the router that holds a PON's network: "Remove it and continue". Offered only for an interface on the router's port towards that OLT, with no clients, no routes, no neighbours and no session on it.
An old gateway the router never heard: after about a minute of checks with no answer, "The old gateway is already off: take the service now". The router still checks that nobody holds the address before it takes it. The same in the take-over by hand.
A PON whose ONTs also use flat VLANs no longer needs a decision: its own VLAN is adopted; the card names the flat VLANs that stay with the other router.
The waiting box is now on the remaining waits of the migration pages. Texts corrected.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 266
1.2.56
Release
Adopt, automatic. The router takes a PON's clients as they are and never writes on the OLT or the ONUs.
The router listens by itself on every client VLAN and S-VLAN of a registered OLT (registered routers only). It never answers there. A listener an admin switched off stays off.
"Adopt as it is": no more decision for a PON where nothing was heard. It shows "listening, no device has spoken yet" and one field for the network.
One confirmation: the router names what to stop on the other router, then waits. When the old gateway stops answering, the router takes the service by itself. The wait can be cancelled and ends by itself (24 h unless changed).
Each device heard keeps its address. A device never heard gets a free address of the same network, checked first.
Devices that speak only IPv6 are now seen and counted.
Every wait on the migration pages shows the stage in words, a countdown to the longest time and what was heard so far.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 265
1.2.55
Release
Huawei OLT: on some models a move into the router's own S-VLAN stopped at its first read, before anything was written ("the OLT refused the request (vendor error)"). Those models answer a question about a VLAN or a service-port that does not exist with a code of their own; the router now asks the OLT's table itself and goes on.
"Adopt as it is" and the way "stay": a network found on a PON is no longer refused only because it lies inside the address space reserved for another OLT of the router. It is refused, as before, when an interface, the CGNAT pool, the PPPoE pool or another port of the router really uses it. The preview says which OLT's reserved space it is.
A port of the router's own never takes a network that an adopted PON holds: the router refuses and names the adopted PON.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 264
1.2.54
Release
Migration wizard: while the router reads the OLT and listens, the page shows the steps, the seconds so far and the longest wait.
Choosing the way after the preview no longer reads the PON's service-ports and ONTs and listens a second time: the router uses the preview's reading while it is fresh (10 minutes), and asks the OLT only for the service-ports' inner VLAN. "Preview again" still reads anew.
The wizard's buttons sit in one row at the bottom right (Back and the next step) and stay in the same place on every step.
One wizard sends one preview or dry run at a time.
Way "stay": when the devices heard sent no IPv4, the preview says so plainly.
A quiet PON is also named when new addresses are chosen together with a typed network; a "stay" run asked with the router's own network is refused.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 263
1.2.53
Release
"dtvsol olt snmp-setup" prints only safe commands for the OLT: no save command, no access list to type, and, on a Huawei OLT, "enable" before "config" and the SNMPv3 version check as a step.
If the OLT already limits SNMP by an access list, a note tells you to allow the router's address in that list; the router never asks for a new one.
The closing lines name "dtvsol olt set <name> --snmp-file <file>" for an OLT already on the router, and remind you to delete the file.
After a failed SNMP test, "olt set" says that nothing was stored, that the old access is kept, and what to check on the OLT.
"olt set" and "olt add" show the result of the SNMP test.
A move is refused in the preview when the OLT's SNMPv3 user has no authentication or no privacy.
Changing a read-only OLT's access no longer touches the router's time service.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 262
1.2.52
Release
Fixed: "dtvsol olt snmp-setup" stopped with an error when typed without --readonly. It now prints the commands for the OLT and the lines for the file.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 261
1.2.51
Release
Migration wizard, the network of a PON: only the preview chooses it, and the move takes exactly the network the preview showed. A typed /24 always wins. A network heard by listening is taken only when a client of this PON has an address inside it. When more than one DHCP network answers on the PON, the router picks none: it names them and asks for the /24.
A typed /24 is compared with what the router heard: when every address heard lies outside it, the preview stops and names both (a guard against a typing mistake).
"New addresses" now always means the router's own network for the PON. A network stored from an earlier listen is shown as such, and one button (or --net4 own) sets it aside.
The listen lasts 20 to 60 seconds and ends as soon as it has what it needs. It reads whole DHCP answers, also large ones.
A move that has started goes on by itself when the browser or the SSH session drops.
Clearer lines: a refused network shows only its real reason; "devices heard, none sent IPv4" instead of "heard nothing"; a warning when no client of the PON uses IPv4, so its ONT would be put back; the line about the OLT's SNMPv3 access names the command that prepares it (dtvsol olt snmp-setup); the age shown at step 1 is the detection's.
A blocked preview no longer offers the move. The CLI stops when its preview fails or is blocked.
An unreadable VLAN list on the router is never taken as "no VLANs".
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 260
1.2.50
Release
Moving a PON into the router's own S-VLAN (migration wizard): the check that the S-VLAN passes between the router and the OLT looked for a wrong interface name on the router and stopped every real move right after the S-VLAN was made on the OLT. Fixed.
The preview, the dry run and the move now refuse with one clear line when the access stored for the OLT cannot do every write of the move and of its way back. A move's writes are never sent another way than the one that can also undo them.
A network that lies inside another OLT's address range on the router is refused for a move too, as it already was for a PON that stays.
When a move cannot go on (the path check fails, or the first ONT is refused), the router removes the S-VLAN it just made on the OLT and what this move made on the router, and says what it removed. It never removes an interface that anything else uses. An ONT left without a service-port by a failed undo is restored at once.
An ONT put back whose client was never heard is judged by its service-port and its online state; the router no longer waits five more minutes for it.
Wizard texts: the network field shows a neutral hint and says when nothing is typed; the lines about addresses say what really happens; the time estimate and the listen seconds are right.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 259
1.2.49
Release
Migration wizard, a PON that sits in another system's S-VLAN: the router now proves its own port towards the OLT from any frame of that PON's clients, IPv6 included. Before, it counted only ARP, DHCP and PPPoE, so a PON whose clients sent none of these in the listen was blocked with "the router could not establish which of its ports leads to this OLT".
The wizard no longer asks which uplink the router is cabled to for such a PON. The router takes the OLT uplink that already carries the found S-VLAN; two ports that form one aggregated link count as one uplink. When it cannot tell, it says what it found and does not ask.
When no device sent IPv4 in the listen, the network you type is used and shown as typed, not measured, with a warning in the preview. The ONTs then move one at a time; an ONT whose client is not back within 5 minutes is put back by the router itself and no further ONT is moved.
Texts corrected: step 2 names both ways; the note about inner VLANs is shown as information, not as an error; the page states what the router does instead of asking where it is cabled.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 258
1.2.48
Release
Migration wizard, a PON that sits in another system's S-VLAN: the wizard no longer asks for an S-VLAN number, and the blocking text "choose another, e.g. …" is gone. The router shows what it found (S-VLAN, inner VLAN, network, gateway) and finds the clients' network and its own port towards the OLT by listening. You choose a way, not a number. Way 1, move to the router's own S-VLAN: client by client, the router writes on the OLT only the lines you accept, the old router is not touched. Way 2 (new), stay in the found S-VLAN: nothing is written on the OLT, the whole PON at once, the router becomes the gateway of the found network and every device it heard keeps its address.
Way 2 needs the old router to stop serving that VLAN first. The router checks this itself, before the start and again right before it takes the gateway address, and does not start while the old gateway answers. It never gives such a PON back by itself, and it raises an alarm when the old router serves that VLAN again. Way 2 is not available on a Router Pair.
A router interface on another system's S-VLAN is kept silent (no IPv6, no ARP answers, no forwarding on it) once the router knows its port towards that OLT; an interface the router itself uses is never touched. dtvsol doctor reports such interfaces.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 257
1.2.47
Release
ZTE OLTs (C320, V1.2.x): the router can now control the ONUs of a ZTE OLT it owns, over the command line: add an ONU, remove it, set its description, suspend and resume it, change its plan or its VLAN. With every change the router names the ONU's serial, and the change is refused when another ONU stands at that place. New: dtvsol olt set --onu-type (ZTE-F625 or ALL; ALL when not set), --onu-type on dtvsol olt ont add, --sn on dtvsol olt ont del and desc.
Limits of this release on ZTE: the speed profiles must already exist on the OLT (the router creates none); no IPTV, no TR-069, no ONU reboot; the ONU's VLAN and the service VLAN must be the same. Proven on a real C320 with a test ONU on an empty port, not yet with a live ONU. Huawei and V-SOL OLTs: nothing changes.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 256
1.2.46
Release
VRFs (registered routers): the router can keep separate routing tables, one per customer or service (VRF-lite). The VLANs, BGP sessions and static routes of a VRF see only each other, so two customers may use the same addresses. Routes pass between two VRFs only for the prefixes you list. Commands: dtvsol vrf, and --vrf on dtvsol vlan, dtvsol bgp and dtvsol route; in the monitor: Routing → VRFs. Every change is shown first, and a change that touches traffic waits 120 seconds for your confirm. Needs BIRD 2.19.3 running (the release brings it).
Limits of this release: VLANs only; not on a Router Pair; subscribers (PPPoE, IPoE), CGNAT, shaping, the lawful log, DNS and OSPF stay in the default VRF. While a VRF exists, the router refuses a return by hand to a release older than this one.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 255
1.2.45
Release
Routing: the router now comes with BIRD 2.19.3. After the update the new BIRD starts by itself in the router's update hours (update policy "auto"); with another policy the router shows "BIRD restart pending" and you start it with dtvsol update bird-restart. The restart drops the BGP and OSPF sessions for a short time. The configuration is checked with the new BIRD first; on a Router Pair the standby goes first.
Switches: a VLAN can be deleted when no port is really set for it (ports that pass every VLAN only by default no longer block); a port can be put back to its default link type (Huawei) and a trunk back to all VLANs (Cisco, Arista, Dell); an unconfigured Huawei port is shown with the switch's own word.
Migration move: on a trunk that already passes every VLAN the router writes nothing, so nothing is left behind on the way back.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 254
1.2.44
Release
Migration move: before a move the router carries its own S-VLAN over its own switches on the path to the OLT by itself (the lines are shown before you accept and removed on the way back). More than one path, or a switch it cannot write: nothing is written and the text names the place.
Switches: Huawei port mode is read correctly after a change and a change is confirmed only when the switch really shows it; a routed Huawei port is shown as routed (portswitch only on request, never on the management port or an uplink); a VLAN can be deleted (never one that a port or an address still uses). VLAN lines proven on Dell.
Device backups: a read-only OLT is read only on request; copies of a removed device are deleted after 90 days; a device added again under an old name starts a new history; the number of versions kept follows the backup server.
Free mode: OLT and switch configuration backup by hand from the monitor, kept on the router.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 253
1.2.43
Release
Migration move: when a client is not back within 5 minutes after its ONT was moved into the router's own S-VLAN, the router now puts the ONT back as it was found, by itself, and then stops the run. This works on OLTs the router owns and on read-only OLTs (through the accepted lines only).
After the put back, the router listens on the S-VLAN where the client was found. If it hears the client, the result says "client online again". If nothing can listen there, the result says "put back, verified on the OLT; the client could not be checked from the router".
If a router record is left behind after a put back, the ONT is marked "needs check" and a critical alarm is raised.
Migration wizard: the page names the button "Convert back". Nobody needs the command line for the way back.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 252
1.2.42
Release
Migration move: before any service-port is touched, the router creates its own S-VLAN on the OLT uplink and checks that the path to the router works. It sends probes in that VLAN and reads the OLT's MAC table for that one VLAN.
Path seen: the move goes on. Path not seen: no client is touched, the S-VLAN made by this run is removed, and the text names the VLAN and the router interface to look at.
Table unreadable: the move is refused, unless the check is switched off on purpose with --no-path-check.
Migration move: removing the router's S-VLAN needs the accepted move; a remade service-port keeps its outbound traffic table; the count of ONTs still moved before the S-VLAN is removed is now correct.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 251
1.2.41
Release
Migration: existing clients are taken as found. The router reads each client's inner VLAN, network, gateway and address from what is already running, and keeps them. Its own numbers are used only for new clients.
Migration move: after you accept (a checkbox and the OLT's name), the router creates its own S-VLAN on the OLT and moves the selected ONTs' service-ports into it, with the same inner VLAN, tables and attributes. It then watches each ONT's client for 5 minutes and stops at the first one that does not come back.
Way back, per ONT: dtvsol migrate convert-back. The router's S-VLAN is removed only if the router made it, it is empty, and only on the router's own uplink.
Read-only OLTs: the router writes only through an in-memory permit, only the accepted lines, and logs them.
New: dtvsol migrate svlan-check <olt> tells whether an S-VLAN is used by another system. An S-VLAN counts as taken when it is used anywhere on the router.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 250
1.2.40
Release
Migration wizard: a PON port whose service-ports are already in the router's S-VLAN, but with no router side yet, no longer stops at "nothing to convert". The wizard offers "make the router side only": it reads the inner VLAN from the OLT, checks it, and creates only the router's interface and networks. Nothing is written on the OLT. The way back removes only the router side.
New OLTs: the S-VLAN is now 2000 + OLT number x 20 + router number. Existing OLTs keep their S-VLAN.
New OLTs: the C-VLAN of a PON port is 100 + slot x 20 + port, the same numbers on every OLT. The S-VLAN tells the OLTs apart. Existing OLTs keep their numbers for old and new ports.
New OLTs: each OLT gets one fixed IPv4 block of the service pool for its PON ports. The router refuses with a clear text when the pool is too small for the block. Existing ports keep their networks.
Nothing changes on a working router at update: no interface, VLAN or network moves.
Doctor: a warning when an OLT's IPv4 block is outside the pool or overlaps another network.
Machines with no IPMI device (virtual machines): the failed openipmi service is switched off.
Texts: the licence line lasts 30 days.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 249
1.2.39
Release
Free mode: the router now works without registration. Routing, CGNAT, BGP and OSPF, PPPoE, IPoE, speed plans, billing connections, DNS, the protections, the monitor and every update work on a router that is not registered. Register at any time with: dtvsol join <code>
Not registered: OLTs, switches and client devices are read and shown, but the router changes nothing on them. Also for registered routers only: migration, the backup server and automatic backups (a backup by hand from the monitor works), making a Router Pair (an existing pair keeps its takeover), promotions, RPKI and RTBH, the suspended page, the speed test server, the web terminal, office and viewer users. A restore from a backup always works.
Not registered: the monitor shows everything. The API and the command line do not give OLT, switch, ONT and TR-069 data, per-client graphs or backup downloads to other programs. Router port graphs, total traffic, the traffic accounting feed and all client management stay open, so billing systems keep working.
Not registered: webhooks, flow export and alarm notifications (email, Telegram, WhatsApp, SMS) are shown and wait. They start by themselves after registration.
Registered routers: nothing changes. The licence line now lasts 30 days and is renewed by itself.
Big OLTs: the background service-port copy is read in pieces, and a live read that fails waits before the next try.
Migration wizard: MAC addresses are read only for the PON port you work on; clearer texts; "Failed to fetch" now names the cause.
OLT uplink ports: the port state and its last change are read in one request, so a slow OLT no longer counts one drop twice.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 248
1.2.38
Release
Big OLTs: the migration wizard no longer reads every service port of the OLT. It reads only the PON port you work on, so "read the OLT again" and the preview answer in seconds on an OLT with thousands of ONTs. The answer "the OLT driver did not finish in time" on these steps is gone.
Whole-OLT service-port copy: for read-only OLTs and big OLTs the router keeps a copy of the service-port table, read in the background every 6 hours. Views that need the whole OLT use this copy and show its age. A write check never trusts a copy older than 12 hours. After a failed read the router waits 6, 12, then 24 hours before the next try. Switch it off for one OLT with: dtvsol olt set <name> --sp-copy off
Read-only OLTs: the promotions check no longer reads read-only OLTs.
Huawei OLTs: a PON port on a board that does not exist, or any other error answer of the OLT, is shown as an error and never as an empty PON port.
OLT uplink ports: a new alarm when an uplink goes up and down (3 changes in 30 minutes). Together with errors on the same port it is critical.
Huawei OLTs the router owns: the light levels of the uplink optical modules are read and shown, with an alarm when the received light is too low.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 247
1.2.37
Release
Port errors: the router now follows the errors of every port it reads: its own ports, the OLT's uplink and PON ports, and the switches' ports. A port with errors that keep growing (10 a minute or more over 10 minutes) turns orange and raises a warning alarm. A port with 1000 errors a minute or more, or with errors together with a link that goes up and down, turns red, blinks and raises a critical alarm. The alarm text names the device, the port and the errors a minute.
Switches: CRC errors a minute are shown for each port of a switch that reports them, in the port's panel, in the errors graph and in the alarm text. A link that goes up and down raises its own alarm.
Router ports: a new errors graph keeps the history. The light levels of the router's own optical modules are shown in the Router hardware panel, with an alarm when the received light is low on a port that has link. Copper cables and modules without readings show nothing.
Client count: the router counts the clients it serves each month and reports the figure to DTVSOL One ("dtvsol clients count").
Licence: texts and checks follow the 60-day licence line.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 246
1.2.36
Release
Fix, Router Pair: the standby router's DHCP check now judges the configuration as a takeover leaves it. Before, the standby reported "fit no (mirror)" and did not take over by itself.
Fix, Router Pair: when the DHCP check fails, the line shows the DHCP server's own error.
Fix, updates: a router that updated from a release older than 1.2.34 could go back to its old release once by itself (the old release's check counted a new automatic BGP blackhole route as a problem). The router now adds these routes only after the update is confirmed.
Updates: stable is the only update channel. "dtvsol update status" shows "update hours".
Backup server: "dtvsol backup server devices" shows the standby line only on the standby router of a pair.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 245
1.2.35
Release
Fix, updates: a router that updated from a release older than 1.2.33 straight to 1.2.34 could go back to its old release by itself (the firewall check did not allow the change made in 1.2.33). The allowance is now kept for every router that still needs it. On a Router Pair, the standby's update no longer reports its backup step as failed.
Fix, Router Pair: when the standby takes over, it now writes the DHCP, DHCPv6 and router-advertisement files before it starts those services.
Migration: the readiness report has new lines and a rehearsal that shows the order of the PONs and each PON's steps without sending anything ("dtvsol migrate report <olt> --rehearsal"). After a PON is moved, the router watches it for 24 hours and raises an alarm when clients are missing. The router can go back by itself on a PON it owns in full; this is off until you turn it on. The monitor's migration page shows all of this.
Adopted PON ports: IPv6 stays off until you turn it on, by command or on the monitor. Turning it on replaces the port's own prefix with the router's and puts it back on the way back; it is refused when the router has no delegation pool.
BGP: a block that is reached only through a route learned by OSPF or iBGP now gets a blackhole of the lowest preference by itself; you no longer turn it off by hand. Blackholes follow address changes at once.
Backup server, Router Pair: each router of a pair sees the pair's archives ("dtvsol backup server list --pair") and can download its peer's ("dtvsol backup server get --peer <kind>/<name>"). Read only.
OLT collection: one OLT that gives no SNMP answer no longer fails the whole run.
Texts: "maintenance window" is now "when a short outage is acceptable"; the update policy shows "update hours".
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 244
1.2.34
Release
Fix: opening the migration readiness report ("dtvsol migrate report", the report page) could stop the router's control service on 1.2.33. Update before you use the report.
Switches, changed default: the router no longer saves a switch's configuration after each change. After this update every existing switch stops saving until you turn "save after a change" on for it (monitor, or "dtvsol switch set <id> --save-after-change on"). Unsaved changes stay listed; "dtvsol switch save <id>" saves them. Changes to the router's own login or SNMP access on a switch are always saved. The old name "autosave" is refused with a clear message.
BGP: for every block the router announces, it now installs a lowest-priority blackhole route by itself, so traffic to unused addresses of the block is dropped and not sent back to the upstream. Your own routes always win, and a block that lies inside a less specific route of the router (another announced block, a static or managed route, an interface network) gets none. If a block is reached only through a less specific route learned by OSPF or iBGP, turn the blackhole off for that block. Turn it off per block with "dtvsol bgp announce set <prefix> --blackhole off". The BGP configuration itself does not change and sessions are not restarted.
ONT renumbering: a port that could not be moved back raises a critical alarm with the ports and the OLT's reason.
DTVSOL One: the migration report is sent in a lighter form, One sees whether the report is allowed and which backups are old, and a refresh is refused with a clear reason while a migration runs on that OLT.
Fixes: several places that could stop the control service on an unexpected stored document now handle it.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 243
1.2.33
Release
Migration without touching the ONUs: the router can adopt an existing PON port ("dtvsol migrate adopt-…"), with a readiness report per OLT that can also be shown in DTVSOL One. A migration runs only when you start it; the wizard no longer asks for a time.
ONT renumbering: "dtvsol olt renumber" moves ONTs to the router's VLAN numbering, step by step, with rollback.
BGP: free local preference per peer, AS-path prepend count, static routes with a preference.
Device backups: the router tells your backup server which OLTs and switches it has; removed devices and the version limit are read from the server.
Switches: several fixes from hardware tests.
Security: the OLT command log is readable by root only and hides passwords and SNMP communities; command logs of earlier versions are removed at the upgrade; OLT error texts are masked in logs. The router's root services run with systemd sandboxing. The last old helper scripts are removed from the router.
Fixes: DHCP ranges and reservations are read more exactly; a re-pair of the same backup server keeps its device list state.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 241
1.2.31
Release
Monitor users from DTVSOL One: when your company manages the monitor's users in DTVSOL One, the router takes its users, roles and passwords from there. The Users page then shows them read-only, with a note. A user can still change the own password on the router. Investigator accounts stay local to the router.
Emergency, when DTVSOL One cannot be reached: root runs "dtvsol monitor local-control on" to manage users on the router again, and "dtvsol monitor local-control off" to give control back.
OLT traffic graphs: port and card graphs of an OLT set to slow polling were empty. They are drawn again.
Monitor: one graph error text was shown in English in Spanish and Portuguese. Translated.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 240
1.2.30
Release
OLT traffic graphs: a wrong counter answer from the OLT (a port answering 0 for one reading) no longer draws a false peak of terabits on the port's graph and on its card's graph. Such a reading is left empty.
Port and card graphs now have a limit: a step above what a port can carry is never drawn.
OLT monitor: the errors line of a PON port showed "{out}" when only one direction had errors. Fixed.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 239
1.2.29
Release
One S-VLAN per OLT: a new OLT gets its own S-VLAN from its number and the router's number (1000 + OLT number × 20 + router number; dtvsol olt numbers). You can always type another one (dtvsol olt set <name> --svlan N).
Nothing changes on OLTs you already have: their S-VLANs, VLANs and clients stay exactly as they are. An OLT taken over from another system keeps the numbers found on it.
The router refuses an S-VLAN or IPTV VLAN that another OLT or VLAN of the router already uses, and says what uses it. The doctor lists OLTs that share an S-VLAN from before.
Before the first client on a new OLT the router reads the OLT once and refuses an S-VLAN that another router already uses there (--no-olt-check when those service-ports are your own).
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 238
1.2.28
Release
Several OLTs on one router: every OLT has its own C-VLAN range, sized by its chassis (dtvsol olt ranges; dtvsol olt set --slots). The router's first OLT keeps its numbers, VLANs and networks exactly as they are.
Before you go back to an older release: once a second OLT has ports, the older release refuses new ports on the first OLT and gives the second OLT's clients no DHCP pool.
Migration listener: the router listens on an old S-VLAN and records which clients are alive and how they connect (DHCP or PPPoE), read-only, for up to 14 days (dtvsol migrate listen; admin only).
The listener's list shows coverage per PON before a migration and can be exported; its data is deleted when the PON's migration is closed.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 237
1.2.27
Release
Rogue DHCP protection: the router drops DHCP and DHCPv6 server replies and router advertisements that come from subscribers, and raises an alarm with the interface and the devices (Security → Protection → Rogue DHCP; dtvsol rogue-dhcp).
Every part has its own switch; an interface with a legitimate DHCP server on the subscriber side (an old BRAS during a migration) can be exempted.
The doctor checks Huawei OLTs for a filter against DHCP server replies on the PON ports with ONTs.
A fix and its undo for owned Huawei OLTs (IPv4), with a preview of the exact lines; off until switched on.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 236
1.2.26
Release
Migrate PON on a big OLT: Detect uses the ONT list the router already keeps (at most 1 hour old) and no longer runs out of time; step 3 shows the uplinks that carry the S-VLAN first, picks one, and offers "Read the OLT again" when the saved reading is old.
Backup server: when the server's daily limit for update backups is reached, the update goes on at once and says why; "dtvsol backup status" shows the backup server's state; new "dtvsol backup server retry" and a "Try now" button.
Switches: uptime no longer jumps between two values; STP off on only some VLANs is an information line, not a warning; a Traffic graph with no data shows "—" instead of "-nan".
PPPoE: an interface whose VLAN no longer exists is shown as missing and raises an alarm; on a Router Pair takeover the PPPoE settings are written before PPPoE starts.
Command line: colours only on a terminal (NO_COLOR is obeyed); "vlan list" and "olt list" columns fit long names; --help works after every update and pair command.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 235
1.2.25
Release
Router Pair, first version: two routers as active and standby, with a shared gateway, mirrored settings and sessions, hand-over by one command and automatic takeover (dtvsol pair).
Deleting a VLAN that PPPoE uses also takes it off PPPoE's interfaces; the other PPPoE sessions stay up.
Migration preview on a big OLT reads only the chosen PON, so it no longer runs out of time; the message says that a preview changes nothing on the OLT.
A first install is only for Ubuntu Server 24.04 LTS on amd64.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 234
1.2.24
Release
Arista EOS switches, and old Cisco and Arista over SSH; the router's SNMP user on Cisco and Arista as those switches take it.
A Traffic tab per switch: the uplink first, then every port's graph by traffic, idle ports folded away.
A switch the router cannot drive yet: one button asks DTVSOL to add it; the text sent is shown first, and the switch page says when it became supported.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 233
1.2.23
Release
The router's SNMP user on a switch, as the switches really take it: on Huawei the keys go through the switch's own password questions; on older Dell firmware without AES the privacy is DES, said so; no access list when the switch is reached through a forward.
The switch form has an SNMP port; the router's own login and SNMP user sit in a "Router access" card on the switch's Overview.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 232
1.2.22
Release
Before the router makes its own user on a switch it checks whether one of that name is already there and asks: take it over, make a differently named one, or cancel.
Huawei: the router's SNMP user is created in the form this firmware accepts.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 231
1.2.21
Release
Traffic graphs for switches: with one click the router makes its own read-only SNMP user on the switch (Huawei and Dell first), then shows per-port traffic, sparklines and graphs, errors and the uplink's load; the keys stay in the router's vault.
The switch doctor checks port errors and a saturated uplink; alarms for both.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 230
1.2.20
Release
A switch change counts as done only when a read of the switch shows it; otherwise the result says "sent, not confirmed" and the change is not counted as proven.
Dell PowerConnect: a port the router shut shows "disabled" (the admin state column was not read on this firmware).
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 229
1.2.19
Release
Dell switches: a port whose description fills its column is no longer lost; a port the router shut shows "disabled"; the serial and the neighbours of older PowerConnect models are read.
Every switch read or change shows it is running: a bar along the top and the pressed button spins until the answer; "Read now" says what came back.
What took on real switches is reported to DTVSOL One, so every operator sees which models and operations are proven on hardware.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 228
1.2.18
Release
The router's own user on a switch: one click makes user "dtvsol" with a strong password the router keeps; your own login can be forgotten or put back later.
Switch doctor: twenty checks per switch (unsaved changes, LLDP, telnet, NTP, logging, trunks passing every VLAN, VLAN 1 on uplinks, spanning tree, backups, outside changes…) with the fix next to each.
Disabled switch ports are drawn grey as a whole.
Alarms about a switch clear by themselves once the switch answers again; a failed change is acknowledged by itself once the same change takes.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 227
1.2.17
Release
Switch ports: a "Default" button resets a port to a fresh state; never the uplink, a LAG or the management port; the port stays shut until you enable it.
Every switch change asks whether to save on the switch; an unsaved change is undone by a restart of the switch, and the page shows "unsaved changes" with Save now.
The switch page says "proven on hardware" per driver once a change took on a real switch of that make.
The switch form no longer lets the browser fill the login fields; a rename keeps the login.
Dell switches: descriptions and VLAN names with spaces are sent quoted.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 226
1.2.16
Release
Backups of your switches: their configuration kept in versions, like the OLTs', with what changed between two versions.
Every OLT and switch is its own item on your dtvsol-backup-server; the Backups page shows each device, its versions and whether it reached the server.
The switch page in sections: Overview, Ports, VLANs, Neighbours — with one search box over ports, descriptions, VLANs and neighbours.
Read-only switches: a switch that is not yours is read like the others and never changed from the router.
DTVSOL One shows each device's backup state and can ask for a backup now.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 223
1.2.15
Release
Switches: the router now sees and controls your network switches — Huawei VRP, H3C Comware, Cisco IOS and compatible, Dell OS6/OS9/OS10, MikroTik RouterOS (SwOS and other switches read-only over SNMP). Add a switch in the monitor's new Switches page or with `dtvsol switch add`; the login is sealed in the router's vault and never shown or reported. Every minute the router reads ports, VLANs, neighbours (LLDP) and health over SNMP (over the CLI when no SNMP community is set); a full read over the switch's own CLI every 15 min. Changes — port up/down, description, mode, PVID, VLAN add/remove/create — are previewed as the exact lines the switch will receive, applied, verified, written to log/switch-commands.jsonl, then saved on the switch (autosave per switch, on by default). `dtvsol switch probe <name>` checks a switch before you add it. All drivers are new: please report what your switch answers.
DTVSOL One: the hardware pages in DTVSOL One show your OLTs (firmware, uptime, boards, PON ports with ONU counts, uplinks) and switches from the router's reports. DTVSOL One may ask the router for the PON list, the ONU list of an OLT, or an ONU restart (never on a read-only OLT), and may store a switch login on your behalf; every such request is signed, answered once, and listed in the router's log.
Fixed: a changed SSH host key of a switch or OLT raises its own alarm instead of "unreachable".
Switches, any brand: a switch that is not one of the listed brands (OEM and white-label units) is added with the same `dtvsol switch add`; the router recognises the command family from the switch's own answers (IOS-like, VRP-like, Comware-like, Dell-like, RouterOS-like) and tells you how sure it is. Set it yourself with `--driver <family>` when you know better. A switch with an unknown command family is monitored over SNMP and stays read-only until you set the family.
OLT uptime: the OLT uptime is now read over SNMP every minute, so it shows for every OLT, including read-only ones; the firmware version keeps coming from the CLI.
DTVSOL One, ONU list: the ONU list of an OLT can be asked per PON port (frame/slot/port), and every ONU carries its last seen time (last up when online, last down when offline).
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 219
1.2.14
Release
Management ports: the ports where the router API (8880), the monitor (8881) and the MikroTik-compatible API (8728) listen can now be changed — Settings → General "Management ports" in the monitor, `dtvsol listen set api|monitor|mkapi <port> --yes`, or POST /listen/set. The firewall follows at once (the allow-list's IPv4 and IPv6 rules, MK-api's own rules), fail2ban's jail moves to the new ports with its bans kept, and only the service that listens there restarts. A port below 1024, SSH's, the ONU pages' pool or one something else listens on is refused. The doctor reports a configured port nothing listens on and a fail2ban jail on other ports than the API's and the monitor's. Fixed: the IPv6 drop rule named MK-api's port 8728 even when it had been changed; MK-api reached the router API on 8880 whatever the configuration said.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 207
1.2.2
Release
- Backups to your own DTVSOL Backup server: pair with dtvsol backup pair; every archive is encrypted with your key and sent; nothing goes to DTVSOL.
- The licence, the router name and certificate, and the security channel come from DTVSOL One; new addresses apply without a re-join; the router checks DTVSOL One for changes once a day.
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 204
1.2.1
Release
- A fresh install starts clean: no false alarms (DHCP, DHCPv6 and radvd only once they are set up; the installer's default route is recognised), a random MikroTik API password shown in the setup summary, integrity baseline taken after the setup.
- dtvsol cgnat set accepts name=value options; a note when dynamic DHCP clients are not registered (they get Internet through CGNAT only once registered).
- The licence refresh is quiet before the router joins DTVSOL One; texts point to DTVSOL One.
- New: dtvsol integrity rebaseline (records what it absorbed).
CVEs fixed
No known CVEs in shipped components fixed in this release.
sequence 201
1.2.0
Release
First public release of the DTVSOL Super Router: one join code from DTVSOL One (Internet → Super Router → Add a Super Router) sets up the router's link, licence and security channel; updates included with the router; signed A/B updates with automatic rollback through apt; monitor in English, Spanish and Portuguese; OLT management (Huawei MA5600T family; ZTE and V-SOL coming), CGNAT, PPPoE/IPoE, BGP/OSPF, TR-069, lawful log with DTVSOL Keeper, flow export to Akvorado.
CVEs fixed
No known CVEs in shipped components fixed in this release.
Routers install releases from the signed stable channel; how and when is set per router (notify by default).